原名「台灣學術線上」
包含TAO期刊庫 + TAO書籍庫 + 論文 + 史料文獻
首頁 | 關於TAO | 瀏覽 | 進階查詢 | 參考工具 | 會員服務 | 已購專書 | RSS服務 | 電子報 | FAQ  
查詢範圍:
   
查詢模式:
熱門查詢詞:
dvd網咖消費者顧客滿意度資優生world
   
   
   
     
   
 
項次 書目
1
題名:尿毒症病患訊息需求量表之建立與測試    
Developing and Testing of Informational Needs Scale in Uremic Patients
著者:林秋菊(Chiu-Chu Lin) ;金繼春(Chi-Chun Chin) ;梁靜祝(Ching-Chu Liang) ;賴永勳(Yung-Hsiung Lai)
出版地區:台灣
出版城市:台北市
學科:醫學綜合
關鍵字:訊息需求 ; 透析治療 ; 尿毒症患者 ; informational needs ; dialysis treatment ; uremic patient
刊名:護理研究
卷期:8卷6期(2000.12)
頁碼:641-651
語言:繁體中文
摘要:
本研究旨在建立並測試「尿毒症病患訊息需求量表」,研究分二階段進行。階段一是發展研究工具(instrument development):研究者查證與訊息需求及透析治療相關文獻,並與腎臟專科醫師、護理師及透析病人討論,再加上本身的臨床經驗來發展問卷項目(item),並由八位專家審閱確立問卷的內容效度。階段二是測試量表的信效度:本研究以內在一致性信度、二週間隔再測信度及因素分析來檢定尿毒症病患訊息需求量表。本研究採問卷訪談法,立意取樣南部22家設有透析中心的醫院或診所之144位尿毒症病人爲研究對象。「尿毒症病患訊息需求量表」經由因素分析萃取出五個因素,分別爲:子解腎臟移植的可行性、認識透析治療、瞭解透析治療對個人、家庭及社會層面的影響、認識尿毒症、瞭解飲食及水份的控制。此五個因素可解釋的總變異量爲49.63%,顯示本量表具有良好的建構效度。在信度方面,「尿毒症病患訊息需求量表」之五個因素的Cronbach's α 與再測信度係數分別介於0.80-0.94與0.70-0.82,顯示本量表具有良好的內在一致性且具穩定性。
The purpose of this study was to develop and to test an instrument for measuring informational needs of uremic patients undergoing dialysis treatment. The study was divided into two phases, developing the instrument and testing validity and reliability. In phase one, the researcher reviewed the literature about informational needs and dialysis treatment, discussed with nephrology physicians, RD clinical nurse specialists and uremic patients and wrote down personal experiences serving as sources for item derivation. Eight experts reviewed the instrument for content validity. In phase two, the psychometric properties of the Informational Needs Scale in Uremic Patients were examined: including internal consistency reliability, two weeks test-retest reliability, and the dimensionality of the Informational Needs Scale in Uremic Patients through factor analysis. A structural interview method was employed in the study. A convenience sample for this study consisted of 144 uremic patients who received dialysis treatment in the dialysis center of twenty-two hospitals in Southern Taiwan. Five factors within the Informational Needs Scale in Uremic Patients were identified by factor analysis, including (1) understanding the feasibility of kidney transplantation, (2)knowledge of dialysis treatment, (3) understanding the influences of dialysis treatment on personal, family and social life, (4) understanding uremia, and (5) understanding dietary and fluid control. These five factors explained 49.36% of variance of the Informational Needs Scale in Uremic Patients. The coefficient of the Cronbach's and test-retest reliability in these five factors of the Informational Needs Scale in Uremic Patients were 0.80-0.94 and 0.70-0.82, respectively. The results showed that the instrument had a satisfactory internal validity and reliability.


    

本卷期目次
護理研究 8卷6期 (2000.12)
主編的話/ 白瑞生
成人氣喘患者的壓力、因應策略與生活品質之關係/ 鄭幸宜戴玉慈郭壽雄姚開屏
承命生根之過程-台灣機構化失能老人遷居的心路歷程/ 陳芷如徐亞瑛
高危險妊娠孕婦在第三孕期之不確定感、壓力及因應策略/ 陳淑蘭陳彰惠
尿毒症病患訊息需求量表之建立與測試/ 林秋菊金繼春梁靜祝賴永勳
921地震北縣新莊災民創傷後反應及其影響因素之探討/ 蘇秀娟李慧貞林建志
分娩護理支持與産婦生産經驗之相關性探討/ 張韶敏陳彰惠
癌症兒童主要照顧者所關注的居家健康照護需求/ 李雅玲高碧霞曾紀瑩駱麗華
出院後永久性結腸造口患者之壓力/ 曾惠珍王秀紅金繼春陳麗糸簡淑媛
 
   
 
   

與TAO合作 | 隱私與版權聲明 | 聯絡方式 | 下載Adobe Reader
地址:台北市中正區(100)北平東路30-12號3樓
電話:(02)2393-6968 傳真:(02)2393-6877
Email: service@wordpedia.com
Wordpedia Family: 學校、企業版入口 | 遠流影音館
Copyright©2011 Wordpedia Co., Ltd. All Rights Reserved.