原名「台灣學術線上」
包含TAO期刊庫 + TAO書籍庫 + 論文 + 史料文獻
首頁 | 關於TAO | 瀏覽 | 進階查詢 | 參考工具 | 會員服務 | 已購專書 | RSS服務 | 電子報 | FAQ  
查詢範圍:
   
查詢模式:
熱門查詢詞:
dvd論後現代主義人權論述臺灣地區2018年"松雀鷹
   
   
   
     
   
 
項次 書目
1
題名:操作技能直接觀察評量一致性之醫事放射教學經驗分享     (10點)
The Experience on Radiological Training for Consistency of Direct Observation of Procedural Skills
著者:溫舒瑜(Wen Shu-Yu) ;黃安潔(Huang An-Jie) ;成佳憲(Cheng Chia-Hsien) ;黃國明(Huang Kuo-Ming)
出版地區:台灣
學科:生命科學 ; 工程技術
關鍵字:信度 ; 效度 ; 一致性 ; Reliability ; Validity ; Consistency
刊名:臺灣應用輻射與同位素雜誌
卷期:10卷2期(2014.6)
頁碼:845-849
語言:繁體中文
摘要: 中文摘要PDF ; 英文摘要PDF

本研究目的使用操作技能直接觀察評量表訂定標準化評分規範,建立評量表單信效度及評分者一致性訓練,以提升教學成效及學習效果。比較兩者評核題目(面膜製作、鉛合金擋塊製作)之表單信效度,並收集15名臨床教師分別觀看教案標準帶、25名醫事實習學生及4名PGY學員側拍影帶之評分者一致性訓練成果。研究結果顯示:(1)兩者評核題目於紀錄審查表之同意度百分比皆達80%,內容符合正確性及適合性,顯示表單具專家效度;其Cronbach's α係數,分別為0.848及0.787,達評量表具信度可接受之標準。(2)教案標準帶之前後測成績,其Pearson相關係數分別為:0.83(P<0.005)、0.87(P<0.001),顯示15名評分者間有顯著正相關,具良好一致性。(3)醫事實習學生側拍影帶之信度分析:Kappa(K)同意度係數:0.83及0.87、Kendall's W值:0.328(P<0.01)及0.032(P<0.01)、ICC(α)組內相關係數:0.83及0.87。(4)PGY學員側拍影帶之信度分析:Kappa(K)同意度係數:0.92及0.86、Kendall's W值:0.45(P=0.00)及0.39(P=0.00)、ICC(α)組內相關係數:0.92及0.86,皆顯示評分者間具有良好評分者一致性。
The purpose of this study is to formulate standardized score criteria by Direct Observation of Procedural Skills(DOPS), to establish reliability and validity for checklist and consistency training of scorer, to elevate performance for training and learning. Comparing reliability and validity of checklist for 2 evaluation subjects(mask making、block making), and collect consistency training results from 15 clinical teachers who watch training videos respectively, 25 medical interns and 4 PGY trainees who make training video. Study results shows: (1) the agree level in record checklist for both subjects are close to 80%, and it matches with correctness and suitability, which indicates checklist is provided with Expert Validity; the Cronbach's αratio are 0.848, 0.787 respectively, which reach the acceptable criteria for reliable checklist. (2) Pre-score and post-score for training video has 0.83(P<0.005) and 0.87(P<0.001) in Pearson correlation coefficient, which shows it is significant positive correlated for 15 scorers and with good consistency. (3) Reliability analysis for side shot video made by Medical interns: Kappa(K) coefficient of agreement: 0.83 and 0.87, Kendall's W value: 0.328(P<0.01)and 0.032(P<0.01), ICC(α) intraclass correlation coefficient:0.83 and 0.87. (4) Reliability analysis for side shot video made by PGY trainees: Kappa(K) coefficient of agreement: 0.92 and 0.86, Kendall's W value: 0.45(P<0.00)and 0.39(P<0.00), ICC(α) intraclass correlation coefficient: 0.92 and 0.86.


    

本卷期目次
臺灣應用輻射與同位素雜誌 10卷2期 (2014.6)
錐形射束電腦斷層之皮膚劑量測量/ 程筠慧陳俊偉張世宗陳信雄
光激發光劑量計應用於乳房攝影劑量量測之研究比較/ 林彥君葉善宏
比較數位乳房攝影自動選取與田口最佳化手動選取暴露參數對影像品質影響/ 林炳辰莊惠珺洪世彥呂宜璇潘榕光
頭頸部放射治療固定模具之設計與誤差分析/ 李哲暐李淞濰陳佳群李昕薇陳信雄
運用實驗最佳化分析醫用直線加速器光子百分深度劑量之最佳調整參數/ 林佳平傅筱如李沛霖林佳輝謝玲鈴
操作技能直接觀察評量一致性之醫事放射教學經驗分享/ 溫舒瑜黃安潔成佳憲黃國明
 
   
 
   

與TAO合作 | 隱私與版權聲明 | 聯絡方式 | 下載Adobe Reader
地址:台北市中正區(100)北平東路30-12號3樓
電話:(02)2393-6968 傳真:(02)2393-6877
Email: service@wordpedia.com
Wordpedia Family: 學校、企業版入口 | 遠流影音館
Copyright©2011 Wordpedia Co., Ltd. All Rights Reserved.