題名:JUNCTION TECHNIQUES FOR PHARYNX AND NECK TREATMENT     (22點)
照野交接技術在治療整個咽部與頸部淋巴的應用
著者:Chien-Yu Lin(林倩?) ;San-Hao Li(李紳豪) ;Li-Hui Chen(陳麗惠) ;Ji-Hong Hong(洪志宏) ;Joseph Tung-Chieh Chang(張東杰)
出版地區:台灣
出版城市:台北市
學科:醫學綜合
關鍵字:單一中心照野技術 ; 交接移動技術 ; 填充物 ; Monoisocentric technique ; Moving junction technique ; Bolus
刊名:Therapeutic Radiology and Oncology
頁碼:77-87
語言:英語
摘要: 中文摘要PDF ; 英文摘要PDF

且曲: 測量與比較照野交接技術( fi e ld junction) 在頭頸部腫瘤併巨大頸部淋巴結的應用。 材制和有注: 取假體( Alderson Rando p凶目叫) 作模擬攝影訂定出照野的中心和範圍, 並作電腦斷層攝影取得假體影像。本實驗所要探討的是單一中心照野技術( monoisocentric t echni que ) 和交接移動技術( moving junction technique) ,並配合上兩種不同的頸部特製填充物( b ol u s ) 。一號填充物只用來調整前後徑差別,而二號填充物是用來調整前後徑及兩側徑差別的特製填充物口用單一中心照野技術或交接移動技術再配合上有無填充物,所以共有六種的不同的組台。首先用電腦治療計劃系統( ADAC c o mp u做出at me nt planning sy st巳m) ,模擬各種不同治療方式,去計算出各種治療方式的劑量分佈曲線,以作為評估擺放熱發光劑量計( T LD ) 的考量。然後,實地模擬各種實際治療情況去照射內含熱發光劑量計的實驗假體各三次,以獲得較接近實際治療所得到的吸收劑量的平均值o 益是: 經過校正, 所有熱發光計量劑的誤差皆在3 %以內。不論是單一中心照野技術或交接移動技術,只要配合上頸部特製填充物都可獲得均勻的劑量分佈。但是如果沒有配合頸部特製填充物的話,較薄的頸部會產生不可接受的高劑量區。然而不可避免的, 還是有少數區域會有劑量分佈不均的現象, 如高劑量區落在前頸接處及側頸部, 低劑量區落在後頭部。不過似乎還是以單一中心照野技術'配合上二號特製填充物,能產生最理想的劑量分佈口回頭比較用T LD實際測量出來和電腦所預測出來的值, 發現大部份的誤差不會超過4 % ' 然而在某些地方, 尤其在照野範圍邊緣( - 1 9 ~ -2 2% ) , 照野交接處( ± 9% ) 及表淺處( -5 ~ - 7 % ) 。 益益: 單一中心照野技術或交接移動技術, 配合上良好的頸部特製填充物, 可應用於臨床實際治療頭頸部腫瘤併巨大頸部淋巴結的病人, 既簡單方便,又有均勻的劑量分佈o至於最適台的方式,還是要依據病人當時的臨床狀況而定口我們認為單一中心照野技術是較為方便的作法。然而, 要配台上良好的頸部特製填充物, 才能使劑量分布更為均句。
Purpose : To probe into junction fields techniques of radiotherapy in head and neck cancer patients who need radical radiotherapy to whole pharyngeal wall and whole neck lymphatics. Material and Methods : We get a simulation film and CT scan image of an Alderson Rando phantom for defining field size and isocenter, and for computer planning system. In this study, we showed dose distribution data of monoisocentric technique and moving junction technique with or without bolus. Two different bolus were used: bolus 1 emphasized only AP depth, bolus 2 emphasized both AP and bilateral depth. So there were six various combinations by either monoisocentric or moving junction with or without bolus. First, isodose distribution by computer planning system was generated to decide where to place TLDs. The average radiation dose in different techniques were obtained by irradiating the phantom packed with TLDs. Results : Both monoisocentric techniques and moving junction techniques with adequate bolus could generate homogenous dose distributions. But if there were no bolus, there was hot area over neck. However there were still uneven dose distribution areas, such as hot areas in anterior superficial neck and lateral neck; cold areas in posterior lower neck. In comparison, monoisocentric technique with bolus 2 tended to create better dose distribution. After comparing data from TLDs and computer planning system, we found most differences were within 4%. However, inconsistency still existed in some locations such as field margins (underestimate 19~22%); junction areas (over/underestimate 9%); superficial areas (underestimate 5~7%). Conclusion : Both monoisocentric techniques and moving junction techniques combined with well-designed bolus can be satisfactorily applied in treating head and neck cancer patients with huge neck lymphadenopathy. There are not only good reproducibility but also good homogeneity. How to choose the optimal technique depends on patients’ clinical status and individual hospital equipments. We suggest that the monoisocentric technique is a more convenient technique in junction fields. However, an well designed bolus is also very important to get a good dose distribution.


    

本卷期目次
Therapeutic Radiology and Oncology
Junction Techniques for Pharynx and Neck Treatment/ Chien-Yu LinSan-Hao LiLi-Hui ChenJi-Hong HongJoseph Tung-Chieh Chang
超薄型熱發光劑量計量測臨床的皮膚劑量/ 黃昭源林招膨林松彥朱鐵吉劉幕台張東浩謝長堯
Intraoperative Extracorporeal Irradiation and RE-Implantation in Treatment of Osteogenic Sarcoma--Two Cases Experience/ Hui-Ling YehJian-Sheng JanTai-Sheng Tan
治療用電子射束在均勻物質中能量損失的數值方法模擬/ 郭力誠李宗其陳俊丞許淑惠
使用蒙地卡羅法EGS4程式計算遮蔽式圓筒狀射源置入器內銥-192射源周圍三維劑量分佈與建立治療計畫系統雛形/ 陳英鑒劉裕明李宗其許任玓張柏菁趙良曉顏上惠
臨床光子射束之蒙地卡羅方法模擬研究/ 林松彥林招膨劉幕台張東浩朱鐵吉
Extraskeletal Osteosarcoma: A Case Report/ Shih-Che ChiuJohn-son LinKu-Hua ChangYuen-Liang Lai
EXTRASKELETAL OSTEOSARCOMA: A CASE REPORT/ Shih-Che ChiuJohnson LinKuo-Hua ChangYuen-Liang Lai
INTRAOPERATIVE EXTRACORPOREAL IRRADIATION AND RE-IMPLANTATION IN TREATMENT OF OSTEOGENIC SARCOMA--TWO CASES EXPERIENCE/ Hui-Ling YehJian-Sheng JanTai-Sheng Tan
臨床光子射束之蒙地卡羅方法模擬研究/ 林松彥林招膨劉幕台張東浩朱鐵吉
超薄型熱發光劑量計量測臨床的皮膚劑量/ 黃昭源林招膨林松彥朱鐵吉劉幕台張東浩謝長堯
JUNCTION TECHNIQUES FOR PHARYNX AND NECK TREATMENT/ Chien-Yu LinSan-Hao LiLi-Hui ChenJi-Hong HongJoseph Tung-Chieh Chang
治療用電子射束在均勻物質中能量損失的數值方法模擬/ 郭力誠李宗其陳俊丞許淑惠
使用蒙地卡羅法EGS4程式計算遮蔽式圓筒狀射源置入器內銥-192射源周圍三維劑量分佈與建立治療計畫系統雛形/ 陳英鑒劉裕明李宗其許任玓張柏菁趙良曉顏上惠
 
   
 
   

與TAO合作 | 隱私與版權聲明 | 聯絡方式 | 下載Adobe Reader
地址:台北市中正區(100)北平東路30-12號3樓
電話:(02)2393-6968 傳真:(02)2393-6877
Email: service@wordpedia.com
Wordpedia Family: 學校、企業版入口 | 遠流影音館
Copyright©2011 Wordpedia Co., Ltd. All Rights Reserved.